基于应变能密度的海上风电装配式混凝土接缝密封性能评价与优化
DOI:
CSTR:
作者:
作者单位:

江苏大学

作者简介:

通讯作者:

中图分类号:

TU599

基金项目:

国家自然科学基金项目(面上项目,重点项目,重大项目)


Evaluation and Optimization of Joint Sealing Performance in Offshore Wind Prefabricated Concrete Structures Based on Strain Energy Density
Author:
Affiliation:

Jiangsu University

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    装配式混凝土结构因其优越的经济性,成为海上漂浮式风电支撑结构的重要选型。然而,接缝作为结构密封的薄弱部位,其密封性能直接关乎浮体结构的安全性与耐久性。针对现有平均和最大接触应力等指标难以表征非均匀接触状态,且现有研究对角部构造处应力集中及潜在渗漏风险认识不足的问题,本文提出一种基于有效接触路径上接触应力积分的综合评价指标——应变能密度,并引入密封能效指数,以综合评价密封性能与压缩荷载之间的协调关系。通过接缝压缩试验与数值模拟,系统研究“角部构造—密封垫”硬度匹配、接缝张开量及错缝量对压缩荷载响应、接触应力演化和密封性能的影响。结果表明,应变能密度随接缝张开量和错缝量增加而下降,能够较稳定地表征非均匀接触条件下密封性能的退化。在0.45 MPa设计控制水压及代表性拼装误差条件下,当密封垫与角部构造硬度分别为65 Shore A和55 Shore A时,密封能效指数最大,表现出较优的综合密封性能。研究结果可为海上风电装配式混凝土结构接缝密封优化设计提供理论依据和工程参考。

    Abstract:

    Prefabricated concrete structures are considered an important option for floating offshore wind support structures because of their economic advantages. However, joints are weak points in the sealing system, and their performance directly affects structural safety and durability. To address the limitations of average and maximum contact stresses in characterizing non-uniform contact and the insufficient understanding of stress concentration and leakage risks at corner configurations, a comprehensive index based on contact stress integration along the effective contact path, termed strain energy density, is proposed. A sealing energy efficiency index is also introduced to evaluate sealing performance relative to compression load. Joint compression tests and numerical simulations were conducted to investigate the effects of hardness matching, joint opening, and offset on compression response, contact stress evolution, and sealing performance. Strain energy density is found to decrease with increasing joint opening and offset, reliably characterizing sealing degradation under non-uniform contact. Under a design water pressure of 0.45 MPa and representative assembly deviations, the highest sealing energy efficiency index is obtained with sealing gasket and corner configuration hardnesses of 65 and 55 Shore A, respectively, indicating favorable sealing performance. The proposed framework provides a theoretical basis for joint sealing design and optimization of prefabricated concrete floating offshore wind structures.

    参考文献
    相似文献
    引证文献
引用本文

王泽念,严佳乐,李传勋,等. 基于应变能密度的海上风电装配式混凝土接缝密封性能评价与优化[J]. 科学技术与工程, , ():

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2026-06-24
  • 最后修改日期:2026-10-03
  • 录用日期:2026-10-26
  • 在线发布日期:
  • 出版日期:
×
关于《科学技术与工程》全新官方网站正式上线的通知公告
关于抵制伪造参考文献学术不端行为的声明
关于规范使用生成式人工智能的声明