基于解耦原型自编码器的光伏故障诊断方法
DOI:
CSTR:
作者:
作者单位:

1.南京工业大学;2.中国电力科学研究院有限公司

作者简介:

通讯作者:

中图分类号:

TM615

基金项目:

江苏省自然科学基金(BK20243045)


Xiao Xuan1, Yi Hui1*,LI Hongtao2
Author:
Affiliation:

1.Nanjing Tech University;2.China Electric Power Research Institute Co., Ltd

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为解决光伏故障诊断任务中正常样本充足而故障样本稀缺所导致的类别不平衡问题,本文提出一种基于解耦原型自编码器(decoupled prototype autoencoder, DPAE)的光伏故障诊断方法。该方法首先采用加权随机采样策略(weighted random sampling strategy, WRSS),缓解正常样本与故障样本类别不平衡造成的训练偏差,接着通过特征注意力机制(feature attention mechanism, FAM)强化关键特征,随后,利用自编码器(autoencoder, AE)学习潜空间表征,并针对故障检测与故障类型识别构建模长-方向解耦机制,其中潜向量模长用于表征样本偏离正常状态的程度,实现正常与故障状态检测;以各类别样本潜向量均值初始化5个可学习类别原型,潜向量与类别原型之间的方向关系用于故障类型判别;同时引入监督对比学习和原型正交约束,增强同类潜向量的方向一致性与不同类别的方向可分性。使用巴西某光伏发电站故障数据集进行验证。实验结果表明:在每类故障仅使用20个训练样本的条件下,所提方法的故障检测准确率达到96.31%,五分类总体诊断准确率达到95.45%,均优于对比方法,验证了所提方法在故障样本稀缺和类别不平衡条件下的有效性。

    Abstract:

    In photovoltaic fault diagnosis, normal samples are usually abundant, whereas fault samples are scarce, which causes class imbalance. To address this problem, a photovoltaic fault diagnosis method based on a decoupled prototype autoencoder (DPAE) was proposed. First, a weighted random sampling strategy (WRSS) was adopted to alleviate the training bias caused by class imbalance between normal and fault samples. Then, important features were enhanced by a feature attention mechanism (FAM). Subsequently, an autoencoder (AE) was used to learn latent-space representations. A norm-direction decoupling mechanism was constructed for fault detection and fault-type identification. The norm of the latent vector was used to characterize the deviation of a sample from the normal operating state and to perform normal/fault detection. Five learnable class prototypes were initialized using the mean latent vector of each class. The directional relationship between the latent vector and the class prototypes was used for fault-type identification. Supervised contrastive learning and a prototype orthogonality constraint were further introduced to enhance the directional consistency of latent vectors within the same class and the directional separability between different classes. The proposed method was evaluated using a fault dataset from a photovoltaic power plant in Brazil. Experimental results show that, with only 20 training samples for each fault class, the fault detection accuracy reaches 96.31%, and the overall five-class diagnostic accuracy reaches 95.45%. Both results are higher than those of the comparison methods. These results demonstrate that the proposed method is effective under conditions of fault-sample scarcity and class imbalance.

    参考文献
    相似文献
    引证文献
引用本文

肖炫,易辉,李红涛. 基于解耦原型自编码器的光伏故障诊断方法[J]. 科学技术与工程, , ():

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2026-06-15
  • 最后修改日期:2026-09-13
  • 录用日期:2026-10-13
  • 在线发布日期:
  • 出版日期:
×
关于《科学技术与工程》全新官方网站正式上线的通知公告
关于抵制伪造参考文献学术不端行为的声明
关于规范使用生成式人工智能的声明
亟待确认版面费归属稿件,敬请作者关注