基于双正交平衡多小波变换的畸变信号电能计量方法
DOI:
CSTR:
作者:
作者单位:

1.北京科技大学自动化学院;2.北京科技大学自动化学院工业过程知识自动化教育部重点实验室;3.中铝郑州有色金属研究院有限公司

作者简介:

通讯作者:

中图分类号:

TM933

基金项目:

国家自然科学基金资助项目(62273033);贵州省科技成果应用及产业化项目(黔科合成果[2024]重大004);


Precise measurement of active energy based on the construction of double orthogonal balanced multiwavelet basis
Author:
Affiliation:

1.School of Automation and Electrical Engineering,University of Science and Technology Beijing;2.Zhengzhou Non-ferrous Metals Research Institute Co,Ltd Of CHALCO

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    针对非线性复杂负载场景下电能精确计量的问题,提出了一种基于双正交平衡多小波多分辨分析的电能计量方法。首先,基于DGHM多小波设计两尺度相似变换矩阵与平衡酉矩阵,构造时频特性可动态优化的双正交平衡多小波基,在保持紧支性与对称性的同时提升逼近阶,并避免预滤波对正交性、对称性的破坏。然后,以分离所得畸变信号与参考畸变信号之间的余弦相似度为适应度函数,采用粒子群优化算法自适应选取最优多小波参数,形成“离线优化-在线计量”两阶段策略,离线阶段建立典型畸变工况下的最优参数库,在线阶段直接调用优化后的多小波基函数,无需实时获取参考畸变信号。最后,利用多小波多分辨分析重构基波与畸变分量,实现畸变工况下电能精确计量。对比非稳态畸变、稳态畸变与复合畸变三类典型工况,实验结果表明,所提方法在畸变信号分离相似度与功率计量误差方面均优于单小波、现有多小波及FFT、STFT、广义S变换等方法,其中非稳态、稳态与复合畸变工况下的有功电能计量误差分别为0.0143%、0.0009%和0.0216%。

    Abstract:

    To address the problem of accurate electric energy metering under nonlinear and complex load conditions, an electric energy metering method based on biorthogonal balanced multiwavelet multiresolution analysis is proposed. First, a two-scale similarity transformation matrix and a balanced unitary matrix are designed based on the DGHM multiwavelet to construct a biorthogonal balanced multiwavelet basis with dynamically optimizable time-frequency characteristics. The constructed basis improves the approximation order while preserving compact support and symmetry, and avoids the degradation of orthogonality and symmetry caused by prefiltering. Then, taking the cosine similarity between the separated distorted signal and the reference distorted signal as the fitness function, particle swarm optimization is employed to select the optimal multiwavelet parameters adaptively. Accordingly, a two-stage strategy of “offline optimization-online metering” is developed. In the offline stage, a library of optimal parameters for typical distortion conditions is established. In the online stage, the optimized multiwavelet basis functions are directly retrieved from the parameter library, without requiring real-time access to reference distorted signals. Finally, multiwavelet multiresolution analysis is employed to reconstruct the fundamental and distortion components, thereby achieving accurate electric energy metering under distorted operating conditions. Comparative experiments are conducted under three typical distortion conditions involving non-stationary, stationary, and composite distorted signals. The results demonstrate that the proposed method outperforms single-wavelet methods, existing multiwavelet methods, the fast Fourier transform (FFT), the short-time Fourier transform (STFT), and the generalized S-transform in terms of distorted-signal separation similarity and power metering error. The active power metering errors under non-stationary, stationary, and composite distortion conditions are 0.0143%, 0.0009%, and 0.0216%, respectively.

    参考文献
    相似文献
    引证文献
引用本文

阎群,周思睿,张保伟,等. 基于双正交平衡多小波变换的畸变信号电能计量方法[J]. 科学技术与工程, , ():