多电源系统切换时中性线不同接地方式对不间断电源电路性能影响的仿真分析
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

TM91

基金项目:

民航宁夏空管分局科技项目(2022)第一作者:廉永乐(1986-),男,汉族,宁夏银川人,硕士,高级工程师。研究方向:数据中心供配电架构及数字化研究。E-mail:lian_yongle@163.com。


Simulation analysis of the performance of UPS power supply circuit with different grounding methods of neutral wire during mult-power systems switching
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    多电源系统在相互切换时因中性线接地方式的不同,将会对交流不间断电源UPS系统性能产生较大影响。首先,基于多电源系统电路等效模型,探讨了不同电路结构的优缺点,并通过搭建MATLAB/Simulink仿真模型,对多电源系统电路性能指标进行了仿真验证;在多电源系统电路基础上,搭建了多电源系统UPS电路MATLAB/Simulink仿真模型,对多电源系统UPS电路关键性能指标进行了仿真实验。其次,以多电源系统UPS电路不产生杂散电流,中性线不分流,中性线接地基准连续,多路输入电源之间、输入电源与输出电源之间、输入电源与旁路电源之间电气隔离等性能指标为优化目标,提出了三种多电源系统UPS电路结构优化方案。最后,搭建三种优化改进电路MATLAB/Simulink仿真模型,对三种UPS电路性能指标进行仿真实验,实验表明改进方案三“多电源系统UPS电源电路加装旁路隔离变压器”具有多电源系统UPS电源电路最优性能指标。

    Abstract:

    When switching between multiple power systems, the performance of the uninterruptible power system (UPS) is greatly affected due to the different grounding modes of the neutral wire. Firstly, based on the equivalent model of multi-power system circuit, the advantages and disadvantages of different circuit structures are discussed, and the performance index of multi-power system circuit is simulated and verified by building MATLAB/Simulink simulation model;Based on the circuit of the multi-power system, the MATLAB/Simulink simulation model of the UPS circuit of the multi-power system is built, and the key performance indexes of the UPS circuit of the multi-power system are simulated. Secondly, three kinds of UPS circuit structure optimization schemes of multi-power system are proposed to optimize the performance indexes of UPS circuit of multi-power system, such as no stray current, no neutral line shunting, continuous neutral line grounding reference, electrical isolation between multiple input power sources, input power and output power sources, and input power and bypass power sources. Finally, three optimized and enhanced circuit MATLAB / Simulink simulation models were constructed, and the performance indexes of the three UPS circuits were simulated. The experimental results demonstrate that the improved scheme three "multi-power system UPS power circuit with bypass isolation transformer" has the optimal performance indexes of the multi-power system UPS power circuit.

    参考文献
    相似文献
    引证文献
引用本文

廉永乐,王明,李帅,等. 多电源系统切换时中性线不同接地方式对不间断电源电路性能影响的仿真分析[J]. 科学技术与工程, 2023, 23(13): 5579-5598.
Lian Yongle, Wang Ming, Li Shuai, et al. Simulation analysis of the performance of UPS power supply circuit with different grounding methods of neutral wire during mult-power systems switching[J]. Science Technology and Engineering,2023,23(13):5579-5598.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2022-09-12
  • 最后修改日期:2023-02-28
  • 录用日期:2022-12-02
  • 在线发布日期: 2023-05-29
  • 出版日期:
×