    《建筑桩基技术规范》(JGJ94—2008)中,给出了用静力触探资料估算混凝土预制桩单桩竖向极限承载力标准值的计算公式,该规范出台几年来,在昆明地区工程实践中却应用不多,大多工程实践对单桩竖向极限承载力的估算仍以经验参数算法为主。本文通过实例,用静力触探资料对昆明某高层建筑进行了单桩竖向极限承裁力标准值的估算,并把估算结果和传统的经验参数法估算结果进行了对比,得出结论,以供参考。

    Abstract:

    The building pile technical specification (JGJ94-2008) has provided the formula to estimate the vertical ultimate bearing capacity of single concrete precast pile with static sounding data, Although being issued for years, the Specification was not used frequently in the engineering practices in Kunming, where the estimating of the vertical ultimate bearing capacity of single pile in most engineering practices are still according to experimental parameter, This text estimates the vertical ultimate bearing capacity of single pile with static sounding data for a high-rise building in Kunming, and compares this result with the result which is estimated by the traditional algorithm based on experimental parameter, comes to a conclusion for reference.

    参考文献
    相似文献
    引证文献
引用本文

杨雁波. 静力触探法估算单桩竖向极限承载力在昆明某高层建筑中的应用[J]. 科学技术与工程, 2012, 12(22): .
yangyanbo. Estimating the vertical ultimate bearing capacity of single pile with static sounding data in a high-rise building in Kunming[J]. Science Technology and Engineering,2012,12(22).

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2012-04-20
  • 最后修改日期:2012-05-07
  • 录用日期:2012-05-03
  • 在线发布日期: 2012-06-20
  • 出版日期:
×
律回春渐,新元肇启|《科学技术与工程》编辑部恭祝新岁!
亟待确认版面费归属稿件,敬请作者关注