Abstract:this paper point out the electro magnetic compatibility(EMC) weakness of the aerostat’s control cabinet according to the deep analysis. This paper also introduces the basic EMC design method, and then explains an integrated way of EMC design. With the associated using cabinet structural design、shielding design、connecting to the earth and filtering, this method improves the Cabinet EMC level, gets a good result.