首页|期刊简介|投稿指南|分类索引|刊文选读|订阅指南|证明资料|样刊邮寄查询|常见问题解答|联系我们
王玲,韩政遒,付素娟,等. T形柱边框架节点套筒灌浆连接抗震分析[J]. 科学技术与工程, 2020, 20(27): 11225-11232.
WANG Ling,韩政遒,付素娟,et al.Seismic Analysis of T-shaped Column Exterior Frame Joint Splicing by Grout-filled Coupling Sleeve[J].Science Technology and Engineering,2020,20(27):11225-11232.
T形柱边框架节点套筒灌浆连接抗震分析
Seismic Analysis of T-shaped Column Exterior Frame Joint Splicing by Grout-filled Coupling Sleeve
投稿时间:2019-12-23  修订日期:2020-06-28
DOI:
中文关键词:  后浇整体式T形柱边框架  套筒灌浆连接  节点抗震性能  有限元分析  轴压比
英文关键词:cast-in-situ monolithic T-shaped column exterior frame  splicing by grout-filled coupling sleeve  seismic behavior of joint  finite element analysis  axial compression ratio
基金项目:河北省建设科技研究计划项目(2015-07);河北省高等学校科学技术研究项目(QN2015143)
           
作者单位
王玲 河北工业大学土木与交通学院
韩政遒 河北工业大学土木与交通学院
付素娟 河北省建筑科学研究院
杨佩剑 河北工业大学土木与交通学院
摘要点击次数: 161
全文下载次数: 63
中文摘要:
      对预制柱连接进行优化,套筒灌浆用于角纵筋连接,其余纵筋绑扎搭接,设计并制作了一个T形柱边框架梁柱节点试件。采用试验和有限元计算,研究梁柱节点在水平地震作用下破坏过程、承载力与变形、延性、刚度与耗能能力,并对轴压比参数进行计算分析。结果表明:优化后梁柱节点呈梁端受弯破坏,节点和预制柱固端未出现明显裂缝;荷载位移骨架曲线表现出较好的塑性变形能力,延性系数接近5;滞回环面积饱满,累积耗能约15 kJ,等效黏滞系数在0.04~0.24之间;随轴压比增加,节点受压损伤区域扩大,延性明显降低。后浇整体式T形柱边框架节点整体性良好,抗震性能较强,弹簧单元用于竖向预制后浇界面黏结作用的简化,数值计算结果与试验表征相符。
英文摘要:
      For optimizing the connection of prefabricated columns, sleeve grouting was used for the connection of corner longitudinal bars, and the rest of the longitudinal bars were tied and overlapped. A scaled specimen of T-shaped column exterior frame joint was designed and fabricated. Experiment and finite element analysis were used to study the failure process, bearing capacity and deformation, ductility, stiffness and energy dissipation capacity of beam-column joints under horizontal earthquake. The axial pressure ratio parameters were calculated and analyzed. The results show that the beam-column joint is subjected to bending damage at the beam end after optimization, and no obvious cracks appear at the joint and the fixed end of the precast column; The load-displacement skeleton curve shows good plastic deformation ability, and the ductility coefficient is close to 5; Hysteresis loop is full, and the cumulative energy consumption reaches about 15 kJ. The equivalent viscosity coefficient is between 0.04 and 0.24; As the axial compression ratio increases, the joint is damaged by compression expand, and the ductility is significantly reduced. The cast-in-situ monolithic T-shaped column exterior frame joint has good integrity and strong seismic performance. The spring elements are used to simplify the adhesion of the vertical precast post-casting interface. The numerical calculation results are consistent with the experiment characterizations.
查看全文  查看/发表评论  下载PDF阅读器
关闭
你是第34984866位访问者
版权所有:科学技术与工程编辑部
主管:中国科学技术协会    主办:中国技术经济学会
Tel:(010)62118920 E-mail:stae@vip.163.com
京ICP备05035734号-4
技术支持:本系统由北京勤云科技发展有限公司设计

京公网安备 11010802029091号