首页|期刊简介|投稿指南|分类索引|刊文选读|订阅指南|资料|样刊邮寄查询|常见问题解答|联系我们
叶爽,张红永,王文新,等. 模拟不同通风方式下综合管廊热力舱热力管道最佳通风区[J]. 科学技术与工程, 2020, 20(16): 6606-6612.
Ye Shuang,et al.Simulating the Optimum Ventilation Zone of Thermal Pipeline in Thermal Chamber of Utility Tunnel under Different Ventilation Modes[J].Science Technology and Engineering,2020,20(16):6606-6612.
模拟不同通风方式下综合管廊热力舱热力管道最佳通风区
Simulating the Optimum Ventilation Zone of Thermal Pipeline in Thermal Chamber of Utility Tunnel under Different Ventilation Modes
投稿时间:2019-07-11  修订日期:2020-06-14
DOI:
中文关键词:  综合管廊 数值模拟 热力舱 通风区
英文关键词:utility tunnel numerical simulation thermal cabin ventilation area
基金项目:
           
作者单位
叶爽 Inner Mongolia University of Technology
张红永 北京维拓时代建筑设计股份有限公司
王文新 内蒙古工业大学土木工程学院
许国强 内蒙古工业大学建筑学院
摘要点击次数: 48
全文下载次数: 31
中文摘要:
      以内蒙古包头市某综合管廊为研究对象,通过实验与CFD数值模拟相结合的方法研究了在不同通风方式下管廊热力舱内不同管径的热力管道所对应的最佳通风区。结果表明:两种通风方式通风区的长度随着热力管道的管径的增加而增加,自然通风、机械排风通风方式下DN300mm、DN400mm、DN500mm、DN600mm管径的最优通风区分别为160 m、166 m、178 m、200 m时可满足巡视人员舒适度要求;在机械送风、机械排风通风方式下,DN300mm、DN400mm、DN500mm、DN600mm管径的最优通风区分别为360 m、370 m、385 m、400 m时即满足要求。研究对综合管廊实际通风设计有一定指导意义。
英文摘要:
      Taking a utility tunnel in Baotou City, Inner Mongolia as the research object, the optimum ventilation area corresponding to different pipe diameters in the thermal cabin of the comprehensive utility tunnel under different ventilation modes was studied by combining experiment with CFD numerical simulation. The results show that the length of ventilation area of two ventilation modes increases with the increase of pipe diameter of thermal pipeline. The optimum ventilation areas of DN300mm, DN400mm, DN500mm and DN600mm pipe diameters under natural ventilation and mechanical ventilation modes are 160 m, 166 m, 178 m and 200 m respectively, which can meet the comfort requirements of inspectors. Under the ventilation mode, the optimum ventilation areas of DN300mm, DN400mm, DN500mm and DN600mm pipe diameters are 360 m, 370 m, 385 m and 400 m respectively, which meet the requirements. The research has certain guiding significance for the actual ventilation design of the utility tunnel.